  1. It’s recommended to use QAlity and QAlity Plus separately and never at the same time.

  2. Update QAlity to the newest version before migration. Make sure it’s working correctly.

  3. Disable or uninstall QAlity and install QAlity Plus

  4. Connect to your database.

  5. If you installed QAlity Plus before migration and added some data then it’s required to delete the records in them so we have empty tables (they will not come back after the migration).

    Code Block
    TRUNCATE TABLE "AO_A89232_TEST_CASE_IN_CYCLE" CASCADE;
    TRUNCATE TABLE "AO_A89232_TEST_CASE_VERSION" CASCADE;
    TRUNCATE TABLE "AO_A89232_TEST_CYCLE" CASCADE;
    TRUNCATE TABLE "AO_A89232_TEST_EXECUTION" CASCADE;
    TRUNCATE TABLE "AO_A89232_TEST_EXECUTION_STEP" CASCADE;
    TRUNCATE TABLE "AO_A89232_ISSUE_TO_TEST_STEP" CASCADE;
    TRUNCATE TABLE "AO_A89232_TEST_STEP" CASCADE;
    Connect to your database.
  6. Use the following command to copy the data from QAlity to QAlity Plus:

    Code Block
    INSERT INTO "AO_A89232_TEST_CASE_VERSION" SELECT * FROM "AO_ABA6C4_TEST_CASE_VERSION";
    INSERT INTO "AO_A89232_TEST_CYCLE" SELECT * FROM "AO_ABA6C4_TEST_CYCLE";
    INSERT INTO "AO_A89232_TEST_EXECUTION" SELECT * FROM "AO_ABA6C4_TEST_EXECUTION";
    INSERT INTO "AO_A89232_TEST_EXECUTION_STEP" SELECT * FROM "AO_ABA6C4_TEST_EXECUTION_STEP";
    INSERT INTO "AO_A89232_ISSUE_TO_TEST_STEP" SELECT * FROM "AO_ABA6C4_ISSUE_TO_TEST_STEP";
    INSERT INTO "AO_A89232_TEST_STEP" SELECT * FROM "AO_ABA6C4_TEST_STEP";
    INSERT INTO "AO_A89232_TEST_CASE_IN_CYCLE" SELECT * FROM "AO_ABA6C4_TEST_CASE_IN_CYCLE";
  7. We are done!

...

  1. It’s recommended to use QAlity and QAlity Plus separately and never at the same time.

  2. Update QAlity to the newest version before migration. Make sure it’s working correctly.

  3. Disable or uninstall QAlity and install QAlity Plus

  4. If you installed QAlity Plus before migration and added some data then it’s required to delete the records in them so we have empty tables (they will not come back after the migration).

    Code Block
    DELETE FROM AO_A89232_TEST_STEP;
    ALTER TABLE AO_A89232_TEST_STEP AUTO_INCREMENT = 1;
    DELETE FROM AO_A89232_TEST_CASE_IN_CYCLE;
    ALTER TABLE AO_A89232_TEST_CASE_IN_CYCLE AUTO_INCREMENT = 1;
    DELETE FROM AO_A89232_ISSUE_TO_TEST_STEP;
    ALTER TABLE AO_A89232_ISSUE_TO_TEST_STEP AUTO_INCREMENT = 1;
    DELETE FROM AO_A89232_TEST_EXECUTION_STEP;
    ALTER TABLE AO_A89232_TEST_EXECUTION_STEP AUTO_INCREMENT = 1;
    DELETE FROM AO_A89232_TEST_EXECUTION;
    ALTER TABLE AO_A89232_TEST_EXECUTION AUTO_INCREMENT = 1;
    DELETE FROM AO_A89232_TEST_CYCLE;
    ALTER TABLE AO_A89232_TEST_CYCLE AUTO_INCREMENT = 1;
    DELETE FROM AO_A89232_TEST_CASE_VERSION;
    ALTER TABLE AO_A89232_TEST_CASE_VERSION AUTO_INCREMENT = 1;
  5. Connect to your database.

  6. Use the following command to copy the data from QAlity to QAlity Plus:

    Code Block
    INSERT INTO AO_A89232_TEST_CASE_VERSION SELECT * FROM AO_ABA6C4_TEST_CASE_VERSION;
    INSERT INTO AO_A89232_TEST_CYCLE SELECT * FROM AO_ABA6C4_TEST_CYCLE;
    INSERT INTO AO_A89232_TEST_EXECUTION SELECT * FROM AO_ABA6C4_TEST_EXECUTION;
    INSERT INTO AO_A89232_TEST_EXECUTION_STEP SELECT * FROM AO_ABA6C4_TEST_EXECUTION_STEP;
    INSERT INTO AO_A89232_TEST_STEP SELECT * FROM AO_ABA6C4_TEST_STEP;
    INSERT INTO AO_A89232_TEST_CASE_IN_CYCLE SELECT * FROM AO_ABA6C4_TEST_CASE_IN_CYCLE;
    INSERT INTO AO_A89232_ISSUE_TO_TEST_STEP SELECT * FROM AO_ABA6C4_ISSUE_TO_TEST_STEP;
  7. We are done!

SQL Server, Azure SQL

  1. It’s recommended to use QAlity and QAlity Plus separately and never at the same time.

  2. Update QAlity to the newest version before migration. Make sure it’s working correctly.

  3. Disable QAlity and install QAlity Plus

  4. If you installed QAlity Plus before and added some data then it’s required to delete the records in them so we have empty tables before migration. Delete all record in these tables (they will not come back after the migration)
    Official Microsoft documentation: Documentation

    Code Block
    AO_A89232_TEST_CASE_IN_CYCLE
    AO_A89232_TEST_CASE_VERSION
    AO_A89232_TEST_CYCLE
    AO_A89232_TEST_EXECUTION
    AO_A89232_TEST_EXECUTION_STEP
    AO_A89232_ISSUE_TO_TEST_STEP
    AO_A89232_TEST_STEP
  5. Connect to your database.

  6. Copy data
    Official Microsoft documentation: Documentation
    from:

    Code Block
    AO_ABA6C4_TEST_CASE_IN_CYCLE
    AO_ABA6C4_TEST_CASE_VERSION
    AO_ABA6C4_TEST_CYCLE
    AO_ABA6C4_TEST_EXECUTION
    AO_ABA6C4_TEST_EXECUTION_STEP
    AO_ABA6C4_ISSUE_TO_TEST_STEP
    AO_ABA6C4_TEST_STEP

    to:

    Code Block
    AO_A89232_TEST_CASE_IN_CYCLE
    AO_A89232_TEST_CASE_VERSION
    AO_A89232_TEST_CYCLE
    AO_A89232_TEST_EXECUTION
    AO_A89232_TEST_EXECUTION_STEP
    AO_A89232_ISSUE_TO_TEST_STEP
    AO_A89232_TEST_STEP
  7. We are done!

...